VCE � Adjustable Vacuum Switches
TECHNICAL DATA
Switch rating
|
0,5(0,2)A / 48Vac-dc
|
Electrical connection
|
6,3x0,8
|
Adjustment range
|
-200…-900 mbar
|
Max static pressure
|
20 bar
|
Hysteresis
|
Fixed (but according to the set-point adjustment)
|
Temperatura pracy
|
-5°C ... +60°C
|
Contact (without pressure)
|
N.O. or N.C.
|
Body material
|
Brass
|
Diaphragm
|
NBR (standard) – other materials on request
|
Threads
|
Taper: G1/8” – G1/4”
|
Protection
|
IP00 (terminals)
IP54 (with CAP1 and CAP10)
|
Mechanical life
|
106 operations
|
Size
|
Body 24 AF
Max. height 48 mm
|
Certifications and Approvals
|
- -
|
Options
|
Set-point adjustment rising
Set-point adjustment falling
|
PROTECTION CAPS
CAP1
Protection: IP54
Material: NBR � FKM � EPDM
|
CAP10
Protection: IP54
Material: NBR
|
|
|
|
|
|
|